Calculation methods

Carbon Capture & Storage Calculation Methods

Formulas and assumptions behind our carbon emissions, CO2 capture, transport, storage, and 45Q calculators.

Carbon emissions (CO2e)

Electricity CO2e (kg) = kWh × grid factor × (1 − renewable %) · Natural gas CO2e (kg) = therms × 5.31

Electricity emissions multiply annual usage by the regional grid emission factor (kg CO2e per kWh from EPA eGRID2023), reduced by any renewable/REC coverage. Natural gas emissions use the EPA GHG Emission Factors Hub combustion constant of 5.31 kg CO2e per therm. The combined total is reported in metric tons (kg ÷ 1,000) and pounds (kg × 2.2046), with equivalencies from the EPA Greenhouse Gas Equivalencies Calculator: 4.6 metric tons CO2e per gasoline vehicle per year and 16.5 tree seedlings per metric ton over 10 years. CO2e (carbon dioxide equivalent) folds in methane and nitrous oxide so the total reflects full climate impact, not just CO2.

Read the full explanation on the calculator page →

CO2 capture cost

Annual CO2 Captured (tons/year) = annual CO2 emissions before capture (tons/year) × (capture rate (%) ÷ 100) · Total Annual Capture Cost ($/year) = annual CO2 captured (tons/year) × capture cost ($/ton)

This calculator estimates the annual cost of capturing CO2 from a point-source emissions stream by applying a capture rate to the facility's pre-capture emissions and multiplying the captured tonnage by a cost per ton.

Data sources: Point-source CO2 capture cost ranges from DOE (Department of Energy), NETL (National Energy Technology Laboratory), and IEA (International Energy Agency) CCS technology assessments; amine-based post-combustion capture cost benchmarks from NETL and industry case studies; capture rate targets and concentration-driven cost variation from IPCC (Intergovernmental Panel on Climate Change) and IEAGHG technical reports; direct air capture cost ranges from DOE and NREL (National Renewable Energy Laboratory) DAC technology assessments.

Read the full explanation on the calculator page →

CO2 storage/sequestration cost

Total Annual Storage Cost ($/year) = annual CO2 volume to store (tons/year) × storage/injection cost ($/ton)

This calculator estimates the annual cost of permanently storing (sequestering) CO2 in a deep geologic formation by multiplying the annual CO2 volume to store by a storage/injection cost per ton.

Data sources: Dedicated geologic CO2 storage (saline aquifer) cost ranges from DOE (Department of Energy), NETL (National Energy Technology Laboratory), and IEA (International Energy Agency) CCS technology assessments; storage cost decomposition (well drilling, injection equipment, site characterization, monitoring) from NETL and industry case studies; MRV program requirements and cost considerations from EPA (Environmental Protection Agency) Underground Injection Control (UIC) Class VI well guidance and IPCC (Intergovernmental Panel on Climate Change) CCS guidelines.

Read the full explanation on the calculator page →

CO2 transport cost

Total Annual Transport Cost ($/year) = annual CO2 volume to transport (tons/year) × pipeline distance (miles) × transport rate ($/ton-mile) · Transport Cost per Ton ($/ton) = total annual transport cost ($) ÷ annual CO2 volume to transport (tons/year)

This calculator estimates the annual cost of transporting captured CO2 by pipeline from a capture facility to a storage or utilization site by multiplying the annual CO2 volume by the pipeline distance and a transport rate per ton-mile, then dividing the total by the volume to show the cost per ton.

Data sources: CO2 pipeline transport cost ranges and per-ton-mile rate benchmarks from DOE (Department of Energy), NETL (National Energy Technology Laboratory), and IEA (International Energy Agency) CCS technology assessments; CO2 conditioning (compression, drying, metering) cost components from NETL and industry case studies; existing U.S. CO2 pipeline infrastructure and EOR-related deployment from DOE and Pipeline and Hazardous Materials Safety Administration (PHMSA) data; onshore pipeline transport cost ranges ($10-30/ton) from IEA and NETL CCS cost chain analyses.

Read the full explanation on the calculator page →

Natural gas + CCS net emissions

Gross CO2 Emissions (tons/year) = (annual natural gas consumption (MMBtu/year) × 117) ÷ 2000 · Captured CO2 (tons/year) = gross CO2 emissions (tons/year) × (capture rate (%) ÷ 100) · Net CO2 Emissions (tons/year) = gross CO2 emissions (tons/year) − captured CO2 (tons/year)

This calculator estimates the net CO2 emissions a natural gas power plant still releases after carbon capture is installed, by converting annual fuel consumption into gross CO2 emissions with the EPA emission factor, then applying a capture rate to split that gross into captured and uncaptured (net) portions.

Data sources: EPA standard natural gas combustion emission factor (117 lb CO2/MMBtu) from the EPA GHG Emission Factors Hub and AP-42; post-combustion capture rate targets (90% commonly cited, 95%+ in newer project targets) from DOE (Department of Energy), NETL (National Energy Technology Laboratory), and IEA (International Energy Agency) CCS technology assessments; net emissions and capture rate policy discussions from IPCC (Intergovernmental Panel on Climate Change) and IEAGHG technical reports.

Read the full explanation on the calculator page →

45Q tax credit value

Annual 45Q Credit Value ($/year) = annual CO2 captured and stored/utilized (tons/year) × credit rate ($/ton)

This calculator estimates the annual value of the federal Section 45Q carbon capture tax credit by multiplying the annual tonnage of CO2 a project captures and stores or utilizes by the per-ton credit rate for its capture pathway.

Data sources: Section 45Q credit rates and eligibility structure from the One Big Beautiful Bill Act (OBBBA, signed July 4, 2025) and 26 U.S.C. 45Q; 45Q history and expansions from the 2008 original enactment, the 2018 FUTURE Act, and the 2022 Inflation Reduction Act; credit claim period and construction-start deadline from current federal statute and IRS guidance.

Read the full explanation on the calculator page →

CCS retrofit capital cost

Total Retrofit Capital Cost ($) = plant capacity (MW) × 1,000 × retrofit cost ($/kW)

This calculator estimates the total capital cost of retrofitting post-combustion carbon capture equipment onto an existing power plant by multiplying the plant capacity in MW by 1,000 (to convert MW to kW) and by the retrofit cost per kW. One quantity ties the calculation together. Total Retrofit Capital Cost ($) = Plant Capacity (MW) × 1,000 × Retrofit Cost ($/kW).

Data sources: retrofit cost ranges from U.S. DOE/NETL post-combustion CCS techno-economic studies.

Read the full explanation on the calculator page →

Direct air capture (DAC) cost

Total Annual DAC Cost ($/year) = annual CO2 removal target (tons/year) × DAC cost ($/ton)

This calculator estimates the annual cost of removing CO2 directly from ambient air using direct air capture (DAC) by multiplying an annual CO2 removal target by a DAC cost per ton.

Data sources: DAC cost ranges and technology assessments from DOE (Department of Energy), NREL (National Renewable Energy Laboratory), and IEA (International Energy Agency) direct air capture technology assessments; liquid solvent and solid sorbent DAC technology descriptions from DOE and industry technical reports; ambient air vs. flue gas CO2 concentration comparison from IPCC (Intergovernmental Panel on Climate Change) and IEAGHG technical reports; Section 45Q DAC credit rate ($180/ton) from the One Big Beautiful Bill Act (OBBBA) and 26 U.S.C. 45Q.

Read the full explanation on the calculator page →

Saline aquifer CO2 storage capacity

Bulk Reservoir Volume (m3) = reservoir area (acres) × 4,046.86 × net reservoir thickness (ft) × 0.3048 · Pore Volume (m3) = bulk reservoir volume (m3) × (porosity (%) ÷ 100) · CO2 Storage Capacity (metric tons) = (pore volume (m3) × (storage efficiency factor (%) ÷ 100) × CO2 density at reservoir conditions (kg/m3)) ÷ 1,000

This calculator estimates the CO2 storage capacity of a saline aquifer formation in metric tons using the standard DOE/NETL volumetric storage resource methodology, which converts the physical dimensions and properties of a formation into a mass-based storage estimate through three sequential steps. Bulk Reservoir Volume (m3) = Reservoir Area (acres) × 4,046.86 × Net Reservoir Thickness (ft) × 0.3048.

Data sources: DOE/NETL volumetric CO2 storage resource methodology and storage efficiency factor ranges from U.S. Department of Energy National Energy Technology Laboratory (NETL) saline formation storage capacity assessment methodologies; porosity ranges for saline sandstone reservoirs from DOE and USGS geologic characterization studies; supercritical CO2 density ranges at storage-depth conditions from IPCC and NETL technical reports.

Read the full explanation on the calculator page →

← All calculation methods