Calculation methods

Long-Duration Storage Calculation Methods

Formulas and assumptions behind our pumped hydro, flow battery, compressed air, and thermal storage calculators.

Pumped hydro storage sizing

Usable Energy Storage (MWh) = (reservoir volume (million m³) × 1,000,000 × head (m) × 0.002725 × (round-trip efficiency (%) ÷ 100)) ÷ 1000

This calculator estimates the usable energy a pumped hydro storage system can store and deliver, given the usable reservoir volume, the head (elevation difference), and the round-trip efficiency.

Data sources: Pumped hydro energy storage physics and gravitational potential energy from mechanical engineering and hydropower fundamentals; pumped hydro round-trip efficiency ranges from DOE (Department of Energy), NREL (National Renewable Energy Laboratory), and IRENA (International Renewable Energy Agency) energy storage technology assessments; global installed pumped hydro storage capacity share from EIA (Energy Information Administration) and IRENA storage databases; pumped hydro site selection and head/volume relationships from hydropower engineering references and industry feasibility studies.

Read the full explanation on the calculator page →

Compressed air energy storage (CAES) efficiency

Energy Output on Discharge (MWh) = energy input for compression (MWh) × (round-trip efficiency (%) ÷ 100) · Energy Lost (MWh) = energy input for compression (MWh) − energy output on discharge (MWh)

This calculator estimates the energy recovered and the energy lost when compressing and later expanding air in a compressed air energy storage (CAES) system, given the electrical energy used to compress the air and the system's round-trip efficiency.

Data sources: CAES technology descriptions and efficiency ranges from NREL (National Renewable Energy Laboratory), DOE (Department of Energy), and IRENA (International Renewable Energy Agency); McIntosh and Huntorf plant specifications from utility and operator documentation; lithium-ion battery round-trip efficiency from industry benchmarks and NREL studies; CAES cost and capacity comparisons from energy storage technology assessments.

Read the full explanation on the calculator page →

Thermal energy storage

Thermal Energy Stored (GJ) = (storage mass (metric tons) × 1,000 × specific heat (kJ/kg-K) × temperature differential (°C)) ÷ 1,000,000 · Thermal Energy Stored (MWh) = thermal energy stored (GJ) × 0.2778

This calculator estimates the thermal energy stored in a sensible-heat storage medium, given the storage mass, the medium's specific heat capacity, and the temperature differential between the hot and cold tanks.

Data sources: Sensible-heat storage physics and specific heat values from NREL (National Renewable Energy Laboratory), DOE (Department of Energy), and IRENA (International Renewable Energy Agency) energy storage technology assessments; molten salt (solar salt) properties and CSP operating temperatures from NREL and Sandia National Laboratories thermal storage research; GJ-to-MWh conversion using the standard 0.2778 MWh/GJ factor (1 GJ = 1,000 MJ; 1 MWh = 3,600 MJ).

Read the full explanation on the calculator page →

Flow battery sizing

Energy Capacity (kWh) = desired power rating (kW) × desired discharge duration (hours) · Required Electrolyte Volume (Liters) = (energy capacity (kWh) × 1000) ÷ electrolyte energy density (Wh/L) · Required Electrolyte Volume (Gallons) = required electrolyte volume (Liters) × 0.264172

This calculator sizes a flow battery for a target continuous power output and discharge duration, then converts the resulting energy capacity into the volume of electrolyte required to store it, given an electrolyte energy density.

Data sources: Flow battery architecture and vanadium redox flow battery (VRFB) energy density ranges from DOE (Department of Energy), NREL (National Renewable Energy Laboratory), and IRENA (International Renewable Energy Agency) energy storage technology assessments; VRFB commercial deployment data from industry reports and operator documentation; liter-to-gallon conversion using the standard 0.264172 U.S. gallons per liter factor.

Read the full explanation on the calculator page →

Flow battery LCOS

Total Installed Cost ($) = system energy capacity (kWh) × installed cost ($/kWh) · Lifetime Cycles = cycles per year × plant life (years) · Lifetime Energy Discharged (MWh) = (system energy capacity (kWh) × lifetime cycles) ÷ 1000 · Lifetime Charging Energy Required (MWh) = lifetime energy discharged (MWh) ÷ (round-trip efficiency (%) ÷ 100) · Lifetime Charging Cost ($) = lifetime charging energy required (MWh) × charging electricity price ($/MWh) · Lifetime O&M Cost ($) = total installed cost ($) × (annual O&M cost (%) ÷ 100) × plant life (years) · Total Lifetime Cost ($) = total installed cost + lifetime charging cost + lifetime O&M cost · LCOS ($/MWh) = total lifetime cost ($) ÷ lifetime energy discharged (MWh)

This calculator estimates the levelized cost of storage (LCOS) for a vanadium redox flow battery (VRFB) project -- the total cost to store and re-deliver electricity across the system's full operating life, divided by the total energy discharged over that life.

Data sources: VRFB installed cost ranges and calendar/cycle life from DOE, NREL, and IRENA energy storage technology assessments; VRFB round-trip efficiency ranges from industry benchmarks and NREL studies; LCOS methodology from standard levelized cost of storage frameworks.

Read the full explanation on the calculator page →

Levelized cost of storage vs. duration

Total Installed Cost ($) = (power rating (MW) × 1000 × power-related cost ($/kW)) + (power rating (MW) × duration (hours) × 1000 × energy-related cost ($/kWh)) · Energy Capacity (kWh) = power rating (MW) × 1000 × duration (hours) · Effective Blended Cost ($/kWh) = total installed cost ($) ÷ energy capacity (kWh)

This calculator separates a storage system's installed cost into a power-related component (fixed regardless of duration) and an energy-related component (scaling directly with duration), then divides the total by the resulting energy capacity to show the effective blended cost per kWh.

Data sources: Storage system cost decomposition (power-related vs. energy-related cost) from DOE (Department of Energy), NREL (National Renewable Energy Laboratory), and IRENA (International Renewable Energy Agency) energy storage technology assessments; vanadium flow battery cost structure from industry benchmarks and NREL studies; duration-cost relationship methodology from standard levelized cost of storage frameworks.

Read the full explanation on the calculator page →

LDES technology comparison

Total Installed Cost ($) = (required power (MW) × 1000 × power-related cost ($/kW)) + (required power (MW) × required duration (hours) × 1000 × energy-related cost ($/kWh)) — applied identically to each technology using its own cost pair

This calculator applies the same installed-cost formula to four long-duration energy storage technologies -- lithium-ion BESS, vanadium flow batteries, pumped hydro, and compressed air energy storage (CAES) -- using each technology's own representative power-related and energy-related cost figures, so the four results are directly comparable at any power and duration. One formula, applied four times, ties the calculation together. Total Installed Cost ($) = (Required Power (MW) × 1000 × Power-Related Cost ($/kW)) + (Required Power (MW) × Required Duration (hours) × 1000 × Energy-Related Cost ($/kWh)). The first term is the fixed power cost (inverters, controls, stack, turbines, compressors) and the second term is the energy cost (cells, electrolyte, reservoir volume, cavern volume) that scales directly with duration. The same formula is repeated for each technology using its own cost pair. The four technologies use these representative, illustrative cost figures: Lithium-Ion BESS -- $150/kW, $250/kWh; Vanadium Flow Battery -- $300/kW, $300/kWh; Pumped Hydro -- $1,800/kW, $50/kWh; CAES -- $1,000/kW, $60/kWh. At the defaults (100 MW, 10 hours): Lithium-Ion BESS = $265,000,000; Vanadium Flow Battery = $330,000,000; Pumped Hydro = $230,000,000; CAES = $160,000,000. Two notes on the model. First, the cost figures are representative, illustrative values for comparison purposes, not precise published benchmarks -- actual project costs vary significantly by scale, site conditions, and market timing, so the relative pattern (how the ranking shifts with duration) is the key insight, not the absolute dollar totals. Second, this calculator isolates the installed-capital-cost dimension and excludes round-trip efficiency, cycle life, operating cost, charging energy cost, site availability, development timeline, permitting, safety, and grid-services capability. Data sources: Storage system cost decomposition and representative technology cost ranges from DOE, NREL, and IRENA energy storage technology assessments; lithium-ion, vanadium flow, pumped hydro, and CAES cost structures from industry benchmarks and NREL studies. Verification: with defaults (100 MW, 10 hours), Lithium-Ion BESS = $265,000,000, Vanadium Flow Battery = $330,000,000, Pumped Hydro = $230,000,000, CAES = $160,000,000.

Read the full explanation on the calculator page →

Pumped hydro LCOS

Total Installed Cost ($) = (power rating (MW) × 1000 × power-related capital cost ($/kW)) + (energy storage capacity (MWh) × 1000 × energy-related capital cost ($/kWh)) · Lifetime Cycles = cycles per year × plant life (years) · Lifetime Energy Discharged (MWh) = energy storage capacity (MWh) × lifetime cycles · Lifetime Charging Energy Required (MWh) = lifetime energy discharged (MWh) ÷ (round-trip efficiency (%) ÷ 100) · Lifetime Charging Cost ($) = lifetime charging energy required (MWh) × charging electricity price ($/MWh) · Lifetime O&M Cost ($) = total installed cost ($) × (annual O&M cost (%) ÷ 100) × plant life (years) · Total Lifetime Cost ($) = total installed cost + lifetime charging cost + lifetime O&M cost · LCOS ($/MWh) = total lifetime cost ($) ÷ lifetime energy discharged (MWh)

This calculator estimates the levelized cost of storage (LCOS) for a pumped hydro storage project -- the total cost to store and re-deliver electricity across the facility's full operating life, divided by the total energy discharged over that life.

Data sources: Pumped hydro capital cost ranges and operating life from DOE (Department of Energy), NREL (National Renewable Energy Laboratory), and IRENA (International Renewable Energy Agency) energy storage technology assessments; pumped hydro round-trip efficiency ranges from DOE and NREL studies; pumped hydro power-related and energy-related cost decomposition from industry benchmarks and feasibility studies; LCOS methodology from standard levelized cost of storage frameworks.

Read the full explanation on the calculator page →

← All calculation methods