Calculation methods

Solar Energy Calculation Methods

Formulas and assumptions behind our solar output, irradiance, shading, community solar, and storage calculators.

Solar panel output

Daily Energy (kWh) = Array Size (kW) × Peak Sun Hours × System Efficiency

Peak sun hours (not daylight hours) represent the hours per day of sunlight at 1,000 W/m² equivalent intensity for a given location. System efficiency accounts for inverter losses, wiring, soiling, and panel temperature derating — typically 75–85% for a well-designed residential system.

Used by: Utility-Scale Solar Array Calculator, Solar Payback Calculator, Net Metering Calculator, Solar Panel Output Calculator

Solar irradiance (plane-of-array from GHI & tilt boost)

POA Irradiance (kWh/m2/day) = GHI (kWh/m2/day) × (1 + Tilt Boost (%) ÷ 100)

This calculator converts a location's average Global Horizontal Irradiance (GHI) into the plane-of-array (POA) irradiance actually reaching a tilted panel surface, using a tilt boost factor that represents the panel orientation. Plane-of-Array Irradiance (kWh/m2/day) = Location Average Horizontal Irradiance (kWh/m2/day) × (1 + Tilt Boost (%) ÷ 100). GHI measures sunlight hitting a flat, horizontal surface, expressed as kWh/m2/day when averaged over a day (equivalent to "peak sun hours"); a flat panel receives sunlight at an angle for most of the day, spreading the same energy over a larger effective area, while tilting the panel toward the sun concentrates more sunlight per unit of panel area. The tilt boost factor captures that gain as a percentage uplift over GHI: 0% for flat/horizontal, roughly 15% for a fixed tilt at latitude (the optimal fixed angle), about 20% for an adjustable seasonal tilt, and around 27% for single-axis tracking. At 4.5 kWh/m2/day of GHI and a 15% fixed-tilt boost, that is 4.5 × (1 + 15 ÷ 100) = 4.5 × 1.15 = 5.18 kWh/m2/day of POA irradiance. The POA figure — not raw GHI — is the right input to a Solar Panel Output Calculator's peak sun hours field, since it represents the sunlight a tilted panel actually converts to electricity. The tilt boost factors are representative planning-level estimates; actual boost varies by latitude (higher latitudes see larger gains) and local climate/cloud patterns (diffuse-dominated climates see smaller gains), and the model does not separately model azimuth, albedo, soiling, or shading. Data sources: NREL National Solar Radiation Database (NSRDB) and PVWatts tool for location-specific GHI data; tilt boost factors from ASHRAE and PVLIB Python; plane-of-array methodology from IEC 61853 and NREL solar resource assessment standards; single-axis tracking performance from utility-scale solar case studies and manufacturer specifications.

Open the calculator →

Tilt & azimuth optimization (fixed-tilt solar orientation)

Recommended Tilt (°) = Site Latitude (°) · Azimuth Loss (%) = (Azimuth Deviation (°))² × 0.0027 · Relative Output (%) = 100 − Azimuth Loss (%)

This calculator ties two solar array geometry decisions — tilt angle and compass direction — to their effect on annual energy capture, using two inputs: your site latitude and your array's azimuth deviation from true south.

Data sources: Solar tilt optimization rule-of-thumb from NREL PVWatts tool and ASHRAE solar resource assessment standards; azimuth loss approximation formula from solar irradiance modeling and PVLIB Python library; latitude-based tilt optimization from utility-scale and residential solar design best practices; seasonal tilt variation data from solar resource assessment tools and solar tracking system performance studies.

Read the full explanation on the calculator page →

Solar shading loss (annual energy loss from partial shading)

Estimated Annual Energy Loss (%) = % Array Shaded × (Daily Shading Duration (% of daylight hours) ÷ 100) × Shading Penalty Multiplier

This calculator estimates the annual energy loss a solar array suffers from partial shading, tying three inputs together: the share of the array affected, the share of daylight hours affected, and a shading penalty multiplier that depends on the inverter/system type.

Data sources: string inverter shading loss multiplier factors from NREL solar performance modeling and field studies; power optimizer and microinverter performance data from manufacturer specifications and utility-scale/residential solar monitoring; panel series-string current bottleneck effects from IEC 61215 and solar system design standards; seasonal and diurnal shading patterns from solar resource assessment tools and site-specific shade analysis case studies.

Read the full explanation on the calculator page →

Bifacial solar gain (bifaciality factor & ground albedo)

Bifacial Energy Gain (%) = (Bifaciality Factor (%) ÷ 100) × Ground Albedo × 50 · Additional Annual Energy (kWh) = Standard Annual Output (kWh) × (Bifacial Energy Gain (%) ÷ 100) · Total Annual Output (kWh) = Standard Annual Output (kWh) + Additional Annual Energy (kWh)

This calculator estimates the bifacial energy gain, the additional annual energy from the rear-side gain, and the total annual output with bifacial gain, tying three inputs together: the standard (monofacial-equivalent) annual output, the bifaciality factor, and the ground albedo. Bifacial Energy Gain (%) = (Bifaciality Factor (%) ÷ 100) × Ground Albedo × 50. The bifaciality factor expresses the rear side's power output relative to the front side under identical illumination — modern bifacial modules typically land in the 70-90% range. Ground albedo measures how much incident light the surface beneath the array reflects back up, on a scale of 0 (no reflection) to 1 (perfect reflection): grass or soil is roughly 0.20, concrete about 0.30, white membrane roofing about 0.55, and fresh snow about 0.80. The 50 multiplier is a representative planning-level coefficient that converts the product of bifaciality and albedo into an expected percentage energy gain over the monofacial-equivalent output. At the defaults (80% bifaciality, 0.20 albedo), that is (80 ÷ 100) × 0.20 × 50 = 0.80 × 0.20 × 50 = 8.0%. Additional Annual Energy from Rear-Side Gain (kWh) = Standard (Monofacial-Equivalent) Annual Output (kWh) × (Bifacial Energy Gain (%) ÷ 100), applying the gain percentage to the standard output the array would produce as a monofacial system — at the defaults (12,000 kWh, 8.0% gain), 12,000 × 0.08 = 960 kWh. Total Annual Output with Bifacial Gain (kWh) = Standard Annual Output (kWh) + Additional Annual Energy from Rear-Side Gain (kWh) — at the defaults, 12,000 + 960 = 12,960 kWh. This is a simplified planning-level approximation: real bifacial gain also depends on mounting height, row spacing, tilt, and the diffuse/direct radiation split, and is typically modeled precisely using specialized software like PVsyst for actual project design. Data sources: bifacial panel technology and bifaciality factor ranges from IEC 60904-1-2 and manufacturer specifications; ground albedo values from solar irradiance measurement standards and PVsyst documentation; bifacial energy gain methodology from bifacial photovoltaic research literature and PVsyst modeling; mounting height and row spacing effects from bifacial PV research and field performance studies.

Open the calculator →

Community solar savings (discounted rate vs. full-rate bill credit)

Community Solar Rate ($/kWh) = Utility Retail Rate ($/kWh) × (1 − Discount (%) ÷ 100) · Monthly Bill Credit ($) = Subscription Share (kWh) × Utility Retail Rate ($/kWh) · Monthly Subscription Cost ($) = (Subscription Share (kWh) × Community Solar Rate ($/kWh)) + Monthly Fee ($) · Monthly Net Savings ($) = Monthly Bill Credit − Monthly Subscription Cost · Annual Net Savings ($) = Monthly Net Savings × 12

This calculator estimates the community solar rate, monthly bill credit, monthly subscription cost, and net monthly and annual savings, tying four inputs together: the monthly subscription share, the utility retail rate, the community solar discount, and the monthly subscription fee.

Data sources: Community solar program structures and discount rates from state-level community solar program documentation and utility filings; bill credit and subscription cost calculation methodology from community solar program terms and conditions; typical community solar discount ranges from NREL and state energy office reports; community solar vs. rooftop solar economics from solar industry analysis and community solar program case studies; PPA vs. community solar comparison from solar financing and procurement literature.

Read the full explanation on the calculator page →

Solar + storage sizing (daily usage, backup duration, critical load, sun hours, derate)

Critical Backup Load (kWh) = Average Daily Electricity Usage (kWh) × (Critical Load Percentage (%) ÷ 100) · Required Battery Usable Capacity (kWh) = (Critical Backup Load (kWh) ÷ 24) × Desired Backup Duration (hours) · Required Solar Array Size (kW DC) = (Average Daily Electricity Usage (kWh) ÷ Peak Sun Hours) ÷ (System Derate Factor (%) ÷ 100)

This calculator estimates the critical backup load, the required battery usable capacity, and the required solar array size, tying five inputs together: the average daily electricity usage, the desired backup duration, the critical load percentage, the peak sun hours, and the system derate factor.

Data sources: Solar array sizing methodology from NREL PV system design standards and solar engineering handbooks; battery usable capacity and backup duration calculation from residential battery storage design standards; critical load percentage and whole-home vs. critical-load backup comparison from residential solar + storage system design practices; peak sun hours and system derate factor from solar irradiance measurement standards and PVsyst documentation; solar + storage system design and sizing from residential solar + storage case studies and industry best practices.

Read the full explanation on the calculator page →

← All calculation methods