Back to Virtual Power Plants (VPPs)
Virtual Power Plants (VPPs) tools

EV Fleet VPP Revenue Calculator

A fleet of bidirectional (V2G-capable) electric vehicles enrolled in a virtual power plant earns money when the grid calls on it to discharge — and managed charging adds a second revenue stream by shifting fleet charging into cheaper off-peak hours. This calculator estimates the annual net revenue for an EV fleet, accounting for V2G share, plugged-in availability, charger and battery limits that cap each dispatch, round-trip efficiency losses on recharge, battery wear, the aggregator's revenue share, and the savings from shifting charging off-peak. It pairs with our VPP Enrollment Revenue Calculator for comparing whole program offers and our Fleet Electrification ROI Calculator for the broader fleet economics picture.

Illustrative placeholder — enter your own estimate of cycle-wear cost.

Illustrative — enter your fleet's actual annual charging energy.

Illustrative — enter your utility's actual peak/off-peak spread.

V2G revenue depends on how many vehicles are bidirectional, how often they are plugged in during events, and the charger power and battery energy that cap each dispatch. Managed charging savings depend on your utility rate structure and how much charging you can shift off-peak.

kWh per vehicle per event
38.4kWh

min(charger kW × hours, usable kWh)

Fleet annual kWh dispatched
11,059kWh

vehicles × V2G share × availability × kWh/event × events × response

Gross V2G revenue
$22,118/yr

fleet kWh × $/kWh

Net annual
$21,701/yr

gross − aggregator − recharge − wear + managed charging

Net per vehicle
$1,085.06/yr

net annual ÷ vehicles

Gross V2G per vehicle
$1,105.92/yr

gross ÷ vehicles

Gross V2G revenue$22,118.40/yr
Aggregator share$6,635.52/yr
Recharge cost$1,228.80/yr
Battery wear cost$552.96/yr
Managed charging savings$8,000.00/yr
Net annual$21,701.12/yr

Duty cycle and charger capacity limit how much of the fleet can actually participate in each event, and V2G is still a maturing market. Managed charging savings depend on your utility rate structure and how much charging you can shift off-peak.

Planning-level estimate — not financial advice. VPP revenue depends on program terms, event frequency, equipment eligibility, V2G vehicle availability, aggregator contracts, and your actual dispatch performance — none of which this calculator can predict. Default figures are based on published summaries or illustrative placeholders; confirm current terms with your utility or aggregator before enrolling.

Results update live as you type. For planning and field-check estimates — always verify against applicable standards and equipment ratings.

How we calculate this →
Insight

Published school-bus V2G estimates vary widely, from about $1,000–2,000 per vehicle per year in some states to $15,000–16,000 in others, depending on utility rates and compensation. Duty cycle and charger capacity limit how much a fleet can actually participate, and V2G is still a maturing market — confirm current program terms before relying on these numbers.

How EV fleet VPP revenue is calculated

An EV fleet enrolled in a virtual power plant (VPP) earns money through two streams: vehicle-to-grid (V2G) dispatch revenue when bidirectional vehicles export energy back to the grid during events, and managed charging savings from shifting fleet charging into cheaper off-peak hours. This calculator builds up from the energy a single vehicle can deliver in one event to the fleet-level annual net.

The dispatchable energy per vehicle per event is the smaller of two limits: the bidirectional charger power multiplied by the event duration, and the usable battery energy available for export. kWh per vehicle per event = min(charger kW × event hours, usable kWh). At the defaults (19.2 kW charger, 2-hour event, 60 kWh usable) that is min(19.2 × 2, 60) = min(38.4, 60) = 38.4 kWh — here the charger power, not the battery capacity, is the binding constraint. Fleet annual kWh dispatched = vehicles × V2G share × availability × kWh per event × events × response rate; at 20 × 1.00 × 0.80 × 38.4 × 20 × 0.90 = 11,059 kWh.

Gross V2G revenue = fleet kWh dispatched × event payment ($/kWh) — $22,118 at $2.00/kWh. Three costs offset that revenue. Aggregator share = gross × aggregator revenue share % — $6,636 at 30%. Recharge cost = (fleet kWh dispatched ÷ round-trip efficiency) × recharge energy cost, because every exported kWh must be replaced and round-trip efficiency losses mean you buy more than you exported — (11,059 ÷ 0.90) × $0.10 = $1,229. Battery wear cost = fleet kWh dispatched × wear cost per kWh discharged, a placeholder for cycle-aging the batteries — 11,059 × $0.05 = $553. Managed charging savings = vehicles × annual charging energy per vehicle × share shifted off-peak × peak/off-peak price spread — 20 × 10,000 × 0.50 × $0.08 = $8,000, reflecting the value of moving half the fleet's charging into cheaper off-peak hours. Net annual = gross − aggregator share − recharge cost − wear cost + managed charging savings = $21,701, or $1,085 per vehicle.

Two practical notes. First, duty cycle and charger capacity are the binding constraints on participation: a vehicle that is on the road during an event cannot dispatch, which is why the availability input matters more than the fleet size, and the charger power caps how much energy can flow in a short event regardless of battery size. Second, V2G is still a maturing market — published school-bus V2G estimates vary widely, from about $1,000–2,000 per vehicle per year in some states to $15,000–16,000 in others, depending on utility rates and compensation structures, so the event payment and events-per-year inputs are the most uncertain assumptions. Data sources: published VPP and V2G program summaries (school-bus and transit fleet pilots); DOE and NREL vehicle-to-grid research; bidirectional charger and round-trip efficiency benchmarks from manufacturer specifications. Verification: 20 vehicles, 100% V2G, 80% availability, 60 kWh usable, 19.2 kW charger, 2-hour event, 20 events, 90% response, $2.00/kWh, 30% aggregator share, 90% RTE, $0.10/kWh recharge, $0.05/kWh wear, managed charging on (10,000 kWh/vehicle, 50% shifted, $0.08 spread) → kWh per vehicle per event = 38.4, fleet annual kWh dispatched = 11,059, gross V2G revenue = $22,118, aggregator share = $6,636, recharge cost = $1,229, wear cost = $553, managed charging savings = $8,000, net annual = $21,701 ($1,085 per vehicle).

Frequently asked questions

What is vehicle-to-grid (V2G)?

Vehicle-to-grid (V2G) lets a bidirectional EV charger export stored battery energy back to the grid when it is most valuable, turning a parked vehicle into a grid asset. A V2G-capable EV, a bidirectional charger, and enrollment in a utility or aggregator program are all required. V2G uses the same charge-low / discharge-high economics as grid-scale battery storage, just with a vehicle battery that also has to be available for driving.

How much can an EV fleet earn from a VPP?

It depends on fleet size, V2G share, plugged-in availability, charger power, event frequency, and the program's payment rate. At the defaults — 20 vehicles, 100% V2G, 80% availability, 19.2 kW chargers, 2-hour events, 20 events per year at $2.00/kWh, 30% aggregator share, and managed charging on — the net annual revenue is about $21,701, or $1,085 per vehicle. Published school-bus V2G estimates vary widely, from about $1,000–2,000 per vehicle per year in some states to $15,000–16,000 in others, depending on utility rates and compensation.

Which fleets are the best fit for V2G?

Fleets with predictable, long dwell times and large batteries — school buses, transit buses, and depot-based delivery fleets — are the best fit, because they are parked and plugged in during the grid events that pay the most. School buses in particular sit idle for much of the day and summer, making them ideal V2G assets. Fleets with high daytime utilization and short dwell times dispatch less energy per event and earn less.

What limits V2G revenue?

Several things this calculator makes explicit: the share of the fleet that is actually bidirectional (V2G-capable), how often vehicles are plugged in during events (availability), the charger power and usable battery energy that cap each dispatch, the round-trip efficiency losses on recharge, battery wear cost, the aggregator's revenue share, and — above all — how many events the utility actually calls. Duty cycle and charger capacity are the binding constraints on participation, and V2G is still a maturing market, so the event payment and events-per-year inputs are the most uncertain assumptions.