A power-only plant throws away most of its fuel as waste heat. Combined heat and power (CHP) captures that heat for hot water, steam or cooling, lifting total efficiency and cutting energy bills. Size a CHP system, see its total efficiency, and estimate net annual savings and payback.

Total system efficiency
77%

electrical + thermal

Fuel input
9.75MMBtu/hr

kW × 3412 ÷ electrical eff × 100 ÷ 1,000,000

Useful heat recovered
4.09MMBtu/hr

fuel input × thermal eff

Net annual savings
$691,822

avoided electricity + avoided boiler fuel − CHP fuel − O&M

Simple payback
3.6years

capital cost ÷ net savings

Results update live as you type. For planning and field-check estimates — always verify against applicable standards and equipment ratings.

How we calculate this →
Insight

A power-only plant at 35% efficiency throws away roughly two-thirds of its fuel as heat. Combined heat and power captures much of that heat for hot water, steam or cooling, lifting total efficiency to around 77% in this example. CHP pays best where a site needs steady heat all year, such as hospitals, food plants and campuses. For fuel cost per MWh, see the Heat Rate & Fuel Cost per MWh Calculator; for full project economics, see the Behind-the-Meter Gas Plant LCOE Calculator.

How CHP efficiency and savings work

Combined heat and power (CHP) — also called cogeneration — burns one fuel to produce electricity and useful heat from the same unit, instead of buying grid power and firing a separate boiler. The efficiency chain starts with fuel input: Fuel Input (MMBtu/hr) = Electrical Output (kW) × 3,412 ÷ Electrical Efficiency (%) × 100 ÷ 1,000,000. The 3,412 converts kW to Btu/hr, dividing by electrical efficiency (as a fraction) gives the fuel energy needed, and ÷1,000,000 converts Btu to MMBtu. At 1,000 kW and 35% electrical efficiency, that is about 9.75 MMBtu/hr of gas.

Useful Heat Recovered (MMBtu/hr) = Fuel Input × Thermal Efficiency ÷ 100 — the share of fuel energy captured as hot water or steam rather than lost up the stack. Total System Efficiency (%) = Electrical Efficiency + Thermal Efficiency, so a 35% electrical / 42% thermal CHP reaches 77% total efficiency versus ~35% for power-only — the core CHP advantage. Annual Electricity (kWh) = Electrical Output × Operating Hours, and the savings side adds two avoided costs: Avoided Electricity Purchases ($) = Annual Electricity × Grid Price, and Avoided Boiler Fuel ($) = Useful Heat ÷ Boiler Efficiency × 100 × Operating Hours × Gas Price — the gas a separate boiler would have burned to make the same heat, adjusted for boiler losses.

Against those savings sit two CHP costs: Annual CHP Fuel Cost ($) = Fuel Input × Operating Hours × Gas Price, and Annual CHP O&M ($) = Annual Electricity × O&M ($/kWh). Net Annual Savings ($) = Avoided Electricity + Avoided Boiler Fuel − CHP Fuel − CHP O&M. Capital Cost ($) = Electrical Output × Installed Cost ($/kW), and Simple Payback (years) = Capital Cost ÷ Net Annual Savings. The model holds efficiencies, prices and hours flat and excludes incentives, standby charges, interconnection, and the cost of unused heat — savings depend on actually using the recovered heat, which is why CHP pays best at hospitals, food plants and campuses with steady thermal load. Data sources: US CHP installations typically 30–40% electrical efficiency and 40–50% thermal efficiency on natural gas (HHV), reaching 75–80% total efficiency; installed costs roughly $2,000–3,000/kW for reciprocating-engine CHP; boiler efficiencies 75–90%. Verification: 1,000 kW, 35% electrical, 42% thermal, 8,000 hours, $4/MMBtu gas, $0.12/kWh grid, 80% boiler, $0.015/kWh O&M, $2,500/kW → fuel input = 9.75 MMBtu/hr, useful heat = 4.09 MMBtu/hr, total efficiency = 77%, net annual savings ≈ $691,800, capital cost = $2.5M, payback ≈ 3.6 years.

Frequently asked questions

What is CHP?

Combined heat and power: one fuel source produces electricity and useful heat together.

What sites benefit most?

Those with steady heat demand, like hospitals, universities and food processing.

Why does heat demand matter?

Savings depend on actually using the recovered heat. Unused heat adds nothing.

Are incentives included?

No. Tax credits and utility programs are not modeled.